We already have a transmitter capable of running 300 watts. Are we ready if LP-250 was to be approved?


That depends on your antenna.  If your station is running a single-bay antena such as a Nicom BKG-77 or a Shively 6812b, your antenna will have a 3 dB loss.  This means that in order to run 100 watts ERP, you will have to run more than 200 watts transmitter power output. 

A two-bay arrnagement of those and other antennas will give you around a 0 dB gain.  This means that you will have to run less power from the transmitter thus allowing you to run up to or close to 250 watts ERP from a 300 watt transmitter.

Your feedline and any equipment between the transmitter and the antenna such as lightning arresors will also contribute to your dB loss.

 